What was found
FLOOR PANEL 242UF HAS FIBER DAMAGE ON UPPER SURFACE. ; / [01] IDENTIFIED PANEL MATERIAL IAW SRM 53-00-50-0I-1 FIG 6 TABLE 6.<BR>FOUND DAMAGE TO UPPER FACESHEET TO BE OUT OF ALLOWABLE LIMITS IAW SRM 53-00-50-1A-1 PARA 4F.<BR>DAMAGE WILL BE REPAIRED IAW SRM 53-00-50-2R-1.<BR>REMOVED 20EA THROUGH INSERTS AND 1EA BLIND INSERT TO FACILITATE REPAIR IAW SRM 53-00-50-2R-1 PARA 3B.<BR>REMOVED DAMAGED PLIES AND CLEANED REPAIR AREA; FABRICATED REPAIR PLIES USING BMS 9-3H2 LOT#1458851-1; OK TO INSTALL IAW SRM 53-00-50-2R-1 PARA 3C-F;K.; [02] VALIDATED APPLICABILITY OF SRM 53-00-50-2R-1; [03] INSPECTED AND VERIFIED CORRECTIVE ACTIONS 1 AND 2. OKAY TO PROCEED WITH REPAIR PER SRM 53-00-50-2R-1.; [04] INSTALLED REPAIR PLIES USING BMS 8-201TY4 LOT#AK0JP9301K;<BR>VACUUM BAGGED; LEAK CHECK GOOD WITH VACUUM GAUGE ID:ATS2586 S/N:5432766772<BR>IAW SRM 53-00-50-2R-1 PARA 3K-L.; [05] INSPECTED AND VERIFIED CORRECTIVE ACTION ITEM 4.; [06] CURED REPAIR PLIES WITH THERMOMETER ID:ATS2208 S/N:43300740WS; UNBAGGED AND TRIMMED IAW SRM 53-00-50-2R-1 PARA 3.M.(1).;