What was found
CORROSION ON SUPPORT BS 986+9 LBL 22 WL 208 ; / [01] REMOVED CORROSION FROM BS 986+9 LBL 22 WL208 IAW SRM 51-10-02-0G-0. REMOVED AMOUNT 1'X1'X 0.045' . ORIGINAL THICKNESS OF MATERIAL 0.080' DUE TO NO LIMITS IN SRM ; SUPPORT FOUND TO BE OUT OF LIMITS. SUPPORT WILL BE REPLACED BY NEW SUPPORT.; [02] VERIFIED; [03] VERIFIED CORROSION OUT OF LIMITS; [04] REMOVED INTERCOSTAL BS986-BS1006 LBL22 WL208 I.A.W SRM 51-40-02-0G-0; [05] LOCATED AND DRILLED NEW INTERCOSTAL BS986-BS1006 LBL22 WL208 I.A.W SRM 51-40-05-0G-0 AND BOEING DWG 147A5600 OK TO INSTALL; [06] INSPECTED LOCATED AND DRILLED NEW INTERCOSTAL BS986-BS1006 LBL22 WL208 I.A.W SRM 51-40-05-0G-0 AND BOEING DWG 147A5600 OK TO INSTALL; [07] INSTALLED NEW INTERCOSTAL BS986-BS1006 LBL22 WL208 I.A.W SRM 51-40-02-0G-0 AND BOEING DWG 147A5600; [08] RII INSPECTED INSTALLED NEW INTERCOSTAL BS986-BS1006 LBL22 WL208 I.A.W SRM 51-40-02-0G-0 AND BOEING DWG 147A5600; [09] INSPECTION COMPLETE; [10] UPDATED CORRODED ELEMENT PART NUMBER IN MEASUREMENTS TABLE.; [11] CERTIFIED UPDATED CORRODED ELEMENT PART NUMBER IN MEASUREMENTS TABLE.