What was found
CRACK IN STRINGER CLIP BS294 STR13L ; / [01] REMOVED CRACKED STRINGER CLIP AT BS 294 STR 13L PER SRM 51-40-02.; [02] FABRICATED NEW ANGLE FROM BAC1489-360#7075T62; LOT# 1464682-1 IAW DWG 141A1311 SH 1 REV:C; [03] INSPECTED FABRICATED NEW ANGLE FROM BAC1489-360#7075T62; LOT# 1464682-1 IAW DWG 141A1311 SH 1 REV:C; [04] APPLIED CHEMICAL CONVERSION AND PRIMER IAW SRM 51-20-01-OG-O; AMM 51-21-72-370-804.; [05] INSPECTED ACTION 4; [06] CERTIFIED REMOVAL OF STRINGER CLIP IN ACTION 1; [07] OK TO INSTALL STRINGER CLIP AT BS294 STR13L AND UPDATE MEASUREMENT TABLE; [08] CORRECTIVE ACTION 7.<BR><BR>OK TO INSTALL STRINGER CLIP AT BS294 STR13L; [09] INSTALLED STRINGER CLIP AT BS294 STR13L PER SRM 51-40-02-0G-0 AND DWG # 141A1311 SH1 REV:C; [10] VERIFIED CORRECTIVE ACTION 9.<BR><BR>INSTALLATION OF STRINGER CLIP AT BS294 STR13L PER SRM 51-40-02-0G-0 AND DWG # 141A1311 SH1 REV:C; [11] VERIFIED CORRECTIVE ACTION 9 WAS INSPECTED AS AN RII STEP. ALL WORK ACCOMPLISHED. <BR><BR>INSTALLATION OF STRINGER CLIP AT BS294 STR13L PER SRM 51-40-02-0G-0 AND DWG # 141A1311 SH1 REV:C; [12] EDITED WORK CAPTURE TO ANNOTATE INSTALLATION WAS INSPECTED AS AN RII.ALL WORK HAS BEEN ACCOMPLISHED. NO FURTHER ACTIONS REQUIRED.