What was found
AFT PIT FLOOR TRACK STA 807+3' TO 807+6' RBL 13.8 WL 156 CORRODED AROUND NUTPLATE HOLES / REMOVED CORROSION ON AFT PIT FLOOR TRACK STA 807+3 TO 807+6 RBL 13.8 IAW SRM 51-10-02 CONFIRMED WITH 10X MAG. MESSURED MATERIAL LOSS AT SPOT A TO BE .014' ORIGINAL .075 REMAINING .061 AND AT SPOT B LOSS OF .005 ORIGINAL .075 REMAINING .070; FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2; REMOVED AND REPLACED DAMAGED FLOOR TRACK IAW SRM 53-00-53-2R-3. P/N 146A7501-31 ATAG WN7344