As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFT CARGO PIT FLOOR TRANSITION SPLICE @STA. 887 APPROXIMATELY WL 156 STR. 26L TO STR. 26R IS CORRODED / AFT CARGO FLOOR SPLICE STRAP AT STA 887 DOES NOT HAVE ENTRIES IN SRM. PART REPAIRABLE BY REPLACEMENT. REMOVED AND REPLACED SPLICE AT STA 887 WL 156 STR 26L - 26R IAW SRM 51-40-02-0G-0 AND DWG 146A7500 REV - P/N 146A9401-39