What was found
PASSENGER CABIN FLOOR;PANEL 241AAF TOP SKIN FIBERS PEELING UP ; / [01] EVALUATED AND FOUND MISSING PLIES ON UPPER SURFACE. NO DAMAGE TO COMPOSITE SUBSTRATE. FOUND TO BE REPAIRABLE IAW SRM 53-00-50-2R-1. TAP TEST GOOD.<BR><BR>CLEANED AND PREPPED IAW SRM 53-00-50-2R-1 STEP 3 A;C; AND E.<BR><BR>VERIFIED MATERIAL IAW SRM 53-00-50-2R-1 TABLE 201. FABRIC (A24484); RESIN (A54258).; [02] VERIFIED STEP 1 AND OK TO BOND; [03] BONDED REPAIR IAW SRM 53-00-50-2R-1 STEP 3 K-M. CURED AT 150 DEGREES (OVEN B0-06 EXP 8-25-21). TAP TEST GOOD.; [04] REPAIRED PASSENGER CABIN FLOOR PANEL 241AFF UPPER SIDE WITH MISSING FIBERS IAW SRM 53-00-50-2R-1 AND SRM 53-00-50-2R-0 REPAIR GENERAL.; [05] VERIFIED STEPS 3-4; [06] AUDITED