What was found
CORROSION ON FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BAY BS807 LBL22 WL158. ; / [01] REMOVED CORROSION 1'X1'X0.005' AT ACB BS 807 LBL22. DAMAGE EXCEED 10% OF ORIGINAL MATERIAL THICKNESS. FOUND TO BE OUT OF LIMIT IAW SRM 53-00-53-1A-2; [02] VERIFIED REMOVED CORROSION 1'X1'X0.005' AT ACB BS 807 LBL22. DAMAGE EXCEED 10% OF ORIGINAL MATERIAL THICKNESS. FOUND TO BE OUT OF LIMIT IAW SRM 53-00-53-1A-2; [03] CALIBRATED TOOL<BR>DIAL DEPTH GAUGE ID:ATS1225<BR>S/N: UNKNOWN; [04] WORK TO BE COMPLETED BY CUST SYSTEM ID : TTG8Q0061VWX; [05] VERIFIED COMPLETE.