What was found
INTERCOSTAL CRACKED IN FWD CARGO BAY BS 500C LBL 25 WL 155 ; / [01] REMOVED FWD CARGO BAY INTERCOSTAL BS 500B-500C LBL 25 WL 155 IAW SRM 51-40-02; [02] LOCATED AND DRILLED NEW INTERCOSTAL BS 500B-500C LBL 25 WL 155; PER SRM 51-40-05 AND DWG 143A7505 SH118. OK TO INSTALL; [03] VERIFIED DRILL LOCATION AND DRILL UP PER SRM 51-40-05 AND DWG 143A7505 SH118. OK TO INSTALL; [04] INSTALLED FWD CARGO BAY INTERCOSTAL BS 500B-500C LBL 25 WL 155 IAW SRM 51-40-02 AND DWG 143A7505 SH 118.; [05] VERIFIED INSTALLATION OF THE INTERCOSTAL BS 500B-500C LBL 25 WL 155 IAW SRM 51-40-02 AND DWG 143A7505 SH 118; [06] UPDATED MEASUREMENTS; [07] VERIFIED MEASUREMENTS; [08] VERIFIED JOB TASK IS ACCOMPLISHED PER SRM 51-40-02; AND BOEING DWG 143A7505.