What was found
CORROSION FOUND ON ACB FWD SHIELD SUPPORT ANGLE FWD UNDERSIDE EDGE; BS 767+2; RBL 24; WL 157 (MARKED) ; / [01] ACB FWD SHIELD SUPPORT ANGLE HAS NO ALLOWABLE DAMAGE LIMIT ON SRM REPAIR BY REPLACEMENT IAW SRM 51-10-02.<BR>REMOVED ACB FWD SHIELD SUPPORT ANGLE BS 767-787; RBL 24; WL 157 IAW SRM 51-40-02.<BR>LOCATED AND DRILLED NEW ACB FWD SHIELD SUPPORT ANGLE PER SRM 51-40-05; DWG#146A0081; ID 43 AND DWG#146A8123; ID 16. <BR>REQUEST OK TO INSTALL; [02] VERIFIED FASTENERS LOCATION AND DRILLED NEW ACB FWD SHIELD SUPPORT ANGLE PER SRM 51-40-05; BOEING DWG 146A0081; 146A8123. OK TO INSTALL.; [03] INSTALLED NEW ACB FWD SHIELD SUPPORT ANGLE IAW SRM 51-40-02-0G--G; DWG 146A0081 REV:-; AND DWG 146A8123 REV:-; [04] VERIFIED INSTALLED NEW ACB FWD SHIELD SUPPORT ANGLE IAW SRM 51-40-02-0G--G; DWG 146A0081 REV:-; AND DWG 146A8123 REV:-; [05] VERIFIED INSTALLED NEW ACB FWD SHIELD SUPPORT ANGLE IAW SRM 51-40-02-0G--G; DWG 146A0081 REV:-; AND DWG 146A8123 REV:-