What was found
EXTERIOR RH AFT OVERWING EMERGENCY EXIT LIGHT INOP / REMOVED AND REPLACED EMERGENCY LIGHTS BATTERY PACK M1671 PER AMM 33-51-06-960-805 AND PERFORMED SATISFACTORY OPERATIONAL TEST PER AMM 33-51-00-710-801 57563U 18AUG2021
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EXTERIOR RH AFT OVERWING EMERGENCY EXIT LIGHT INOP / REMOVED AND REPLACED EMERGENCY LIGHTS BATTERY PACK M1671 PER AMM 33-51-06-960-805 AND PERFORMED SATISFACTORY OPERATIONAL TEST PER AMM 33-51-00-710-801 57563U 18AUG2021