What was found
FWD CARGO LEFT TRANSITION ANGLE HAS LIGHT CORROSION FROM BS 500C-500I IN AND AROUND SEVERAL W/P HOLES / BLENDED LIGHT CORROSION IAW SRM 51-10-02; DAMAGE REMOVAL FROM STA 500G TO 500I WAS WITHIN LIMITS IAW SRM 53-00-53-1A-2. TREATED IAW SRM 51-20-01 & PRIMED IAW SOPM 20-41-02. DAMAGE REMOVAL FROM STA 500C TO 500F WAS OUT OF LIMITS IAW SRM 53-00-53-1A-2. ACCOMPLISHED SPLICE REPAIR FROM STA 50.B& 9' 500F AND 9' IAW SRM 53-00-53-2R-5