What was found
CRACKED INTERCOSTAL AT FWD WET AREA BS321 LBL45 WL208. ; / [01] NO ALLOWABLE DAMAGE FOUND FOR THIS PART; PART REPAIRABLE BY REPLACEMENT<BR>IAW SRM 51-10-02-OG 0; [02] REMOVED CRACKED INTERCOSTAL FROM BS 312- BS 328 IAW SRM 51-40-02-0G-0; [03] LOCATED AND DRILLED NEW INTERCOSTAL ITEM #141A5410U12 IAW SRM 51-40-05-0G-0 ; OK TO INSTALL; [04] VERIFIED LOCATE AND DRILL OF NEW INTERCOSTAL PER SRM 51-40-05; OK TO INSTALL; [05] INSTALLED NEW INTERCOSTAL AT BS312-BS328 LBL45 WL208 ITEM 141A5410U12 IAW SRM 51-40-02-0G-0; DWG#141A5400; [06] CORRECTED MEASUREMENTS; [07] CORRECTING REFERENCE FOR CORRECTIVE ACTION ITEM 1: NO ALLOWABLE DAMAGE FOUND FOR THIS PART; PART REPAIRABLE BY REPLACEMENT IAW SRM 51-10-02-0G-0; [08] VERIFIED NO ALLOWABLE DAMAGE FOUND FOR THIS PART; PART REPAIRABLE BY REPLACEMENT IAW SRM 51-10-02-0G-0 ANDINSTALLED NEW INTERCOSTAL AT BS312-BS328 LBL45 WL208 ITEM 141A5410U12 IAW SRM 51-40-02-0G-0; DWG#141A5400