What was found
CRACKED INTERCOSTAL AT FWD WET AREA BS353 LBL11 WL208. ; / [01] VERIFIED APPLICABILITY OF SRM 53-10-51-0I-2 FOR IDENTIFICATION AND NO FOUND ALLOWABLE DAMAGE FOR THIS PART. REPAIRABLE BY REPLACEMENT IAW SRM 51-10-02-0G-0; PAR.9.C.; [02] REMOVED INTERCOSTAL AT FWD WET AREA BS 344- BS360 LBL11 WL208 IAW SRM 51-40-02-0G-0; [03] ADDED PART REQUIREMENT; [04] VERIFIED CORRECTIVE ACTION 1 PER SRM 51-10-02-0G-0; PAR.9.C; [05] LOCATED AND DRILLED NEW INTERCOSTAL AT FWD WET AREA BS344-BS360 LBL11 WL208 IAW SRM 51-40-05-0G-0 AND DWG 141A5230. OK TO INSTALL.; [06] VERIFIED LOCATED AND DRILLED NEW INTERCOSTAL AT FWD WET AREA BS344-BS360 LBL11 WL208 IAW SRM 51-40-05-0G-0 AND DWG 141A5230. OK TO INSTALL.; [07] INSTALLED NEW INTERCOSTAL AT FWD WET AREA BS344-BS366 LBL11 WL208 IAW SRM 51-40-02-0G-0 AND DWG#141A5230; [08] RII INSPECTED GOOD INSTALLATION PER SRM 51-40-02 AND DWG 141A5230.; [09] VERIFIED GOOD INSTALLATION OF NEW INTERCOSTAL PER SRM 51-40-02 AND DWG 141A5230; JOB COMPLETE.