What was found
CRACK FOUND AT INTERNAL MAIN CABIN BEAR STRAP STA 294.5 JUST BELOW STR 8-R; CRACK LENGTH :1.496' / [01] INSTALLED EWIS PROTECTION AS PER 0-60-07-913-801; [02] REMOVED FASTENERS FOR ACCESS PER SRM 51-40-02; [03] PERFORMED HFEC INSP ON CUT OUT AT INTERNAL MAIN CABIN BEAR STRAP STA 294.5 JUST BELOW STR8-R. IAW B 737 NDT PART 6 51-00-00 PROCE 23. TOOL USED NORTEC 600. BC 166317. CALIB DUE 10-12-21. NO CRACKS FOUND.; [04] PERFORMED HFEC ROTATORY INSP ON OPEN FASTENER HOLES AT INTERNAL MAIN CABIN BEAR STRAP STA 294.5 JUST BELOW STR8-R. IAW B 737 NDT PART 6 51-00-00 PROCE 16. TOOL USED NORTEC 600. BC 166317. CALIB DUE 10-12-21. NO CRACKS FOUND.; [05] PERFORMED HFEC COUNTERSUNK INSP ON OPEN FASTENER HOLES AT INTERNAL MAIN CABIN BEAR STRAP STA 294.5 JUST BELOW STR8-R. IAW B 737 NDT PART 6 53-30-00 PROCE 3. TOOL USED NORTEC 600. BC 166317. CALIB DUE 10-12-21. NO CRACKS FOUND.; [06] LATE ENTRY : CUT OUT DAMAGED 2'X1' AT BEAR STRAP STA. 294.5 JUST BELOW STR. 8-R IAW B737-700 SRM 53-10-01-2R-6 REPAIR 6; [28] VERIFIED 25;26;AND 27;COMPLETED; [29] REMOVED EWIS PROTECTION AS PER 20-60-07-913-801; [30] VERIFIED STEP 29. OK TO APPLY TOP COAT; [31] CUT OUT DAMAGED AREA FABRICATED AND INSTALLED REPAIR DOUBLER AND TRIPLER PER SRM 53-10-01-2R-6 REPAIR 6;