What was found
CORROSION ON FCB L/H FLOOR-TO-SIDEWALL SUPPORT; BS 460+12; LBL 24; WL 156 (MARKED) ; / [01] VEREFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORRISION FROM FCB L/H FLOOR-TO-SIDEWALL SUPPORT; BS 460+12; LBL 24; WL 156. P/N 143A7501-80; IN AREA 0.7' X 0.5' X 0.021' DEEP; ORIGINAL THICKNESS 0.040' FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2 PER 4.A(2) FIG. 103 DETAIL A <BR>TOOL USED <BR>-DEPTH GAGE <BR>ID:ATS2472. S/N: UNKNOWN. DUE DATE: 06/2022; [03] VERIFIED REMOVED CORRISION FROM FCB L/H FLOOR-TO-SIDEWALL SUPPORT; BS 460+12; LBL 24; WL 156. P/N 143A7501-80; IN AREA 0.7' X 0.5' X 0.021' DEEP; ORIGINAL THICKNESS 0.040' FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2 PER 4.A(2) FIG. 103 DETAIL A.; [04] PART WAS FOUND TO BE OUT OF LIMITS. REMOVAL OF FLOOR TO SIDEWALL SUPPORT WAS ACCOMPLISHED ON CUSTOMER CARD: TTG8Q004G1EL STEP 11 AND WILL BE FABRICATED AND INSTALLED ON CUSTOMER CARD: TTG8Q0060HB5; [05] VERIFIED FLOOR TO SIDEWALL SUPPORT WAS ACCOMPLISHED ON CUSTOMER CARD TTG8Q004G1EL STEP 11 AND WILL BE FABRICATED AND INSTALLED ON CUSTOMER CARD: TTG8Q0060HB5