What was found
CORROSION ON FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BAY BS727D+13 - BS727D+19 RBL21 WL156. ; / [01] VERIFIED APPLICABILITY OF SRM 53-60-53-0I-2 FOR IDENTIFICATION AND SRM 53-60-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION FROM FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BAY BS 727D +13''- BS727D+19'' RBL21 WL157; P/N 143A7502-1 IN AREA 0.3''X0.2''X0.018'' DEEP; ORIGINAL THICKNESS 0.040''; FOUND TO BE OUT OF LIMIT IAW SRM 53-00-53-1A-2 PAR. 4.A.(2) FIG. 103.<BR>TOOL USED: DIAL DEEP GAGE ID:ATS2452; DUE: 06/2022; [03] CORRECTED MEASUREMENT; [04] CORRECTED: REMOVED CORROSION FROM FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BAY BS 727D +13''- BS727D+19'' RBL21 WL157; P/N 143A7502-2 IN AREA 0.3''X0.2''X0.018'' DEEP; ORIGINAL THICKNESS 0.040''; FOUND TO BE OUT OF LIMIT IAW SRM 53-00-53-1A-2 PAR. 4.A.(2) FIG. 103.<BR>TOOL USED: DIAL DEEP GAGE ID:ATS2452; DUE: 06/2022; [05] VERIFIED REMOVED CORROSION FROM FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BAY BS 727D +13''- BS727D+19'' RBL21 WL157; P/N 143A7502-2 IN AREA 0.3''X0.2''X0.018'' DEEP; ORIGINAL THICKNESS 0.040''; FOUND TO BE OUT OF LIMIT IAW SRM 53-00-53-1A-2 PAR. 4.A.(2) FIG. 103.; [06] THIS DISCREPANCY WILL ACCOMPLISHED ON CARD TTG8Q0060TCS; [07] VERIFIED; CONFIRMED REPLACEMENT ON TTG8Q0060TCS; JOB COMPLETE.; [08] VERIFIED; CONFIRMED REPLACEMENT ON TTG8Q0060TCS; JOB COMPLETE.