Service difficulty report · Support · Boeing 7377H4

Difficulty date
August 10, 2021
Submitted
September 7, 2021
Operation
Air carrier
Aircraft
N755SA
Make and model
Boeing 7377H4
Aircraft serial
27871
Aircraft time
74,723 hours, 44,099 cycles
Part
Support
Condition
Corroded
Location
Bs 500b Rbl 24
Stage of operation
IN
How discovered
9
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

CORROSION ON FLOOR TO SIDEWALL SUPPORT AT FWD CARGO BAY BS500B+19 RBL24 WL156. ; / [01] EVALUATED CORROSION; FOUND 0.015 REMOVED FROM ORIGINAL 0.040 IN 1'X1' AREA FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2 USING DIAL DEPTH GAUGE ATS 2472 S/N UNKNOWN; [02] VERIFIED EVALUATED CORROSION; FOUND 0.015 REMOVED FROM ORIGINAL 0.040 IN 1'X1' AREA FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2 USING DIAL DEPTH GAUGE ATS 2472 S/N UNKNOWN; [03] REMOVED FLOOR TO SIDEWALL SUPPORT BS 500A-500D; RBL24; WL 156 PER SRM 51-40-02-0G-0.; [04] LOCATED; DRILLED AND APPLIED CHEMICAL CONVERSION COATING TO FLOOR TO SIDEWALL SUPPORT AT FCB BS500B TO BS500D RBL24 WL156 PER SRM 51-40-05-0G-0; DWG 143A7500 AND AMM 51-21-41-370-802; [05] LOCATED; DRILLED AND APPLIED CHEMICAL CONVERSION COATING TO FLOOR TO SIDEWALL SUPPORT AT FCB BS500A TO BS500D RBL24 WL156 PER SRM 51-40-05-0G-0; DWG 143A7500 AND AMM 51-21-41-370-802; [12] OK TO INSTALL FLOOR TO SIDEWALL SUPPORT; [13] INSTALLED FLOOR TO SIDEWALL SUPPORT PER SRM 51-40-02-0G-0; DWG 143A7500; AND DWG143A7505; [14] VERIFIED STEP 13; [15] RII INSPECTED ACTION 13; [16] INSTALLED FLOOR TO SIDEWALL SUPPORT PER SRM 51-40-02-0G-0; DWG 143A7500; AND DWG 143A7505

More about the Boeing 737-7H4