What was found
CORROSION ON FLOOR TO SIDEWALL SUPPORT AT FWD CARGO BAY BS500B+19 RBL24 WL156. ; / [01] EVALUATED CORROSION; FOUND 0.015 REMOVED FROM ORIGINAL 0.040 IN 1'X1' AREA FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2 USING DIAL DEPTH GAUGE ATS 2472 S/N UNKNOWN; [02] VERIFIED EVALUATED CORROSION; FOUND 0.015 REMOVED FROM ORIGINAL 0.040 IN 1'X1' AREA FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2 USING DIAL DEPTH GAUGE ATS 2472 S/N UNKNOWN; [03] REMOVED FLOOR TO SIDEWALL SUPPORT BS 500A-500D; RBL24; WL 156 PER SRM 51-40-02-0G-0.; [04] LOCATED; DRILLED AND APPLIED CHEMICAL CONVERSION COATING TO FLOOR TO SIDEWALL SUPPORT AT FCB BS500B TO BS500D RBL24 WL156 PER SRM 51-40-05-0G-0; DWG 143A7500 AND AMM 51-21-41-370-802; [05] LOCATED; DRILLED AND APPLIED CHEMICAL CONVERSION COATING TO FLOOR TO SIDEWALL SUPPORT AT FCB BS500A TO BS500D RBL24 WL156 PER SRM 51-40-05-0G-0; DWG 143A7500 AND AMM 51-21-41-370-802; [12] OK TO INSTALL FLOOR TO SIDEWALL SUPPORT; [13] INSTALLED FLOOR TO SIDEWALL SUPPORT PER SRM 51-40-02-0G-0; DWG 143A7500; AND DWG143A7505; [14] VERIFIED STEP 13; [15] RII INSPECTED ACTION 13; [16] INSTALLED FLOOR TO SIDEWALL SUPPORT PER SRM 51-40-02-0G-0; DWG 143A7500; AND DWG 143A7505