What was found
CORROSION ON SHIELD IN FWD CARGO BAY FORWARD OF DOOR BS430 RBL 21 WL 156 ; / [01] UPDATED MEASUREMENT TABLE; [02] EVALUATED CORROSION; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0; [03] VERIFIED CORROSION OUT OF LIMITS AND PART TO BE REPLACED PER SRM 51-10-02; [04] REMOVED SHIELD; BS 420-440; RBL 21; WL 156 PER SRM 51-40-02-0G-0.; [05] LOCATED AND DRILLED NEW SHIELD AT FCB BS430 RBL21 WL156 PER SRM 51-40-05-0G AND DWG 143A0080.; [06] VERIFIED LOCATE AND DRILL UP OF NEW SHIELD PER SRM 51-40-05 AND DWG 143A0080.; [07] UPDATED PARTS TABLE; [08] OK TO INSTALL SHIELD; [09] OK TO INSTALL; [10] INSTALLED FWD CARGO BAY FORWARD OF DOOR SHIELD IAW SRM 51-40-02-0G-0; DWG # 143A0080; [11] VERIFIED INSTALLED FWD CARGO BAY FORWARD OF DOOR SHIELD IAW SRM 51-40-02-0G-0; DWG # 143A0080; [12] CORRECTED MEASUREMENT TABLE; [13] CERTIFIED STEP 1