What was found
FCB GUSSET BS 500D STRINGER 21 L/H IS CRACKED ; / [01] EVALUATED CRACK; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0; [02] VERIFIED EVALUATED CRACK; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0; [03] REMOVED GUSSET BS 500D STR 21L PER SRM 51-40-05-0G-0; [04] LOCATED AND DRILLED NEW GUSSET AT BS 500D STR 21L PER SRM 51-40-05-0G-0 AND DWG 143A7902. OK TO INSTALL; [05] REMOVED GUSSET BS 500D STR 21L PER SRM 51-40-02-0G-0; [06] VERIFIED ITEMS 3;4 AND 5; [07] VERIFIED LOCATED AND DRILLED NEW GUSSET AT BS 500D STR 21L PER SRM 51-40-05-0G-0 AND DWG 143A7902. OK TO INSTALL; [08] INSTALLED GUSSET AT BS 500D STR 21L PER SRM 51-40-02-0G-0 AND DWG 143A7902; [09] VERIFIED STEP 8; [10] VERIFIED CORRECTIVE ACTION STEP 8.; [11] APPLIED CIC ON GUSSET BS 500D STR 21L PER AMM 51-21-91-620-802; [12] VERIFIED STEP 11; [13] VERIFIED CORRECTIVE ACTIONS 8 TO 12. <BR><BR>GUSSET AT BS500D; S-21L REPLACED; [14] FCB GUSSET AT BS500D; S-21L HAS BEEN REPLACED. ALL WORK ACCOMPLISHED.