What was found
AFT CARGO BAY FLOOR PANEL SPLICE STRAP AT BS 767+4 HAS OVERSIZE HOLES RBL 10 TO LBL10 WL 156 ; / [01] UPDATED MEASUREMENT TABLE; [02] EVALUATED OVERSIZE HOLES ON SPLICE STRAP; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0; [03] RECEIVED NEW STRAP ON PO# 829373 NEW PART WILL BE INSTALLED ON FAULT # TTG8Q0060TDE; [04] VERIFIED NEW STRAP RECEIVED; INSTALLATION ON TTG8Q0060TDE; JOB COMPLETE.