What was found
CRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS 312 TO BS 328 AND RBL 31 FWD GALLEY AND LAV ; 202-341467 / [01] TOOL USED DIGITAL CALIPER P/N: DIGITAL150; S/N: AE-412605; DUE DATE: 25MAY22; [02] REPLACED WEB-INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS 312 TO BS 328 AND RBL 31 FWD GALLEY AND LAV AND FASTENER I.A.W B737-700 SRM 51-40-02; SRM 51-10-02 PARAGRAPH 9 AND DWG 141A5400 SHEET 39 REV -.; [03] TASK CARD COMPLETE AND CERTIFIED AS RII.