What was found
CORROSION ON AFT BULKHEAD TO FLOOR SUPPORT ANGLE AT AFT CARGO BAY BS947 LBL2 TO LBL9 WL179. ; / [01] EVALUATED CORROSION; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0; [02] VERIFIED CORRECTIVE ACTION ENTRY 1.; [03] REMOVED ACB AFT BULKHEAD TO FLOOR SUPPORT; BS 947 ; IAW SRM 51-40-02-0G-0.; [04] LOCATED AN DRILLED NEW AFT BULKHEAD TO FLOOR SUPPORT ANGLE AT AFT CARGO BAY BS 947; WL179 IAW DWG 149A8117 SH6 AND SRM 51-40-05; [05] VERIFIED STEP 4; [06] VERIFIED LOCATE AND DRILL OF THE AFT CARGO BAY SUPPORT ANGLE AT BS947 PER DWG 149A8117 SH6 AND SRM 51-40-05; [07] OK TO INSTALL; [08] OK TO INSTALL BULKHEAD TO FLOOR SUPPORT; BS 947; LBL 2 - LBL 9; [09] INSTALLED ACB AFT BULKHEAD TO FLOOR SUPPORT; BS 947 ; IAW SRM 51-40-02-0G-0 AND DWG 149A8117.; [10] VERIFIED INSTALLATION OF ACB AFT BULKHEAD-TO-FLOOR SUPPORT; BS 947; LBL 2; PER SRM 52-40-02 AND DWG 149A8117; [11] UPDATED MEASUREMENT TABLE; [12] CERTIFIED STEPS 1 AND 11; [13] VERIFIED ALL WORK COMPLETE THIS TASK