What was found
CRACKED SUPPORT ANGLE BEHIND WATER SERVICE PANEL AT AFT CARGO BAY BS914 RBL12 WL170. ; / [01] EVALUATED CRACK; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0; [02] REMOVED OLD SUPPORT ANGLE; LOCATED AND DRILLED NEW ANGLE ALL PER SRM 51-40-02; SRM 51-40-05; AND DWG 147A7221; OK TO INSTALL; [03] VERIFIED CORRECTIVE ACTIONS 1 AND OK TO INSTALL; [04] INSTALLED NEW SUPPORT ANGLE PER SRM 51-40-02-0G-0 AND DWG 147A7221; [05] VERIFIED NEW BS914 RBL12 WL170 SUPPORT ANGLE INSTALLATION PER SRM 51-40-02-0G-0 AND DWG 147A7221; [06] WORKSCOPE COMPLETE