What was found
CORROSION ON FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BAY BS767 - BS727D RBL21 WL156. ; / [01] REMOVED CORROSION IN 1'X60' AREA REMOVED 0.015 FROM ORIG 0.040 FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2 USING DIAL DEPTH GAUGE PART#ATS 2472 S/N UNKNOWN.; [02] VERIFIED CORRECTIVE ACTION ENTRY 1.; [03] REMOVED ACB RH FLOOR TO SIDEWALL SUPPORT; BS 727-767 RBL21; IAW SRM 51-40-02-0G-0; [04] LOCATED AND DRILLED NEW FLOOR TO SIDEWALL SUPPORT PER SRM 51-40-05 AND DWG 146A7500; [05] VERIFIED LOCATED AND DRILLED NEW FLOOR TO SIDEWALL SUPPORT PER SRM 51-40-05 AND DWG 146A7500; [06] APPLIED TOPCOAT AND CIC PER CUSTOMER CARD#TTG8Q004E7BQ. REQUEST OK TO INSTALL.; [07] INSPECTED AND VERIFIED CORRECTIVE ACTION ITEM 6. OKAY TO INSTALL FLOOR TO SIDEWALL SUPPORT.; [08] INSTALLED ACB FLOOR TO SIDEWALL SUPPORT BS 727 - 767; RBL 21; WL 156 IAW SRM 51-40-02; DWG#146A7500; DWG# 146A7502.; [09] FINAL INSPECTION. JOB COMPLETE PER SRM 51-40-02; DWG#146A7500; DWG# 146A7502.; [10] FINAL INSPECTION. JOB COMPLETE PER SRM 51-40-02; DWG#146A7500; DWG# 146A7502.; [11] FINAL INSPECTION. JOB COMPLETE PER SRM 51-40-02; DWG#146A7500; DWG# 146A7502.