What was found
CORROSION ON FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BAY BS869 RBL19 WL165. ; / [01] VERIFIED APPLICABILITY OF SRM 53-60-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION FROM TO SIDEWALL SUPPORT AT AFT CARGO BAY BS869 RBL19 WL165; IAW SRM 51-10-02-0G-0;P/N 146A7502-6 IN AREA 0.8''X0.3''X0.020''DEEP. ORIGINAL THICKNESS 0.040'' FOUND TO BE OUT F LIMITS IAW SRM 53-00-53-1A-2; PAR. 4.A(2); FIG. 103; DETAIL C.; [03] REMOVED FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BAY BS867 TO BS887 IAW SRM 51-40-02-0G-0; [04] VERIFIED REMOVED CORROSION FROM TO SIDEWALL SUPPORT AT AFT CARGO BAY BS869 RBL19 WL165; IAW SRM 51-10-02-0G-0;P/N 146A7502-6 IN AREA 0.8''X0.3''X0.020''DEEP. ORIGINAL THICKNESS 0.040'' FOUND TO BE OUT F LIMITS IAW SRM 53-00-53-1A-2; PAR. 4.A(2); FIG. 103; DETAIL C.; [05] FABRICATED AND LOCATED AND DRILLED NEW SIDEWALL SUPPORT FROM MAT. P/N BAC1496-377 #7075T62; LOT 1466224-1 AT AFT CARGO BAY BETWEEN BS867 TO BS887; RBL 19 WL 165. IAW SRM 51-40-05-0G 0 AND DWG 146A7500 APPLIED CHEMICAL CONVERSION COATING IAW SRM 51-20-01 OK TO PRIMER; [06] VERIFIED REMOVED FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BAY BS867 TO BS887 IAW SRM 51-40-02-0G-0 AND VERIFIED FABRICATED; LOCATED; AND DRILLED NEW SIDEWALL SUPPORT FROM MAT. P/N BAC1496-377 #7075T62; LOT 1466224-1 AT AFT CARGO BAY BETWEEN BS867 TO BS887; RBL 19 WL 165 IAW SRM 51-40-05-0G 0 AND DWG 146A7500