What was found
CORROSION ON FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BAY BS727E+3 RBL21 WL156 ; / [01] REMOVED CORROSION ON FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BS 727E+3 RBL21 WL;156;DIMENSIONS L=1.8' W=1.5'DEPTH .008 IAW SRM 51-10-02 PARA#15 ;EVALUATED TO SIDEWALL SUPPORT;ORIGINAL THICKNESS .040 REMAINING THICKNESS .032 DAMAGE EXCEED 10% OF ORIGINAL THICKNESS FOUND TO BE OUT LIMITS IAW SRM 53-00-53-1A-2 ALLOWABLE DAMAGE 2;TOOL USED MICROMETER S/N 87172291 DATE DUE 05/2022.; [02] VERIFIED REMOVED CORROSION ON FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BS 727E+3 RBL21 WL;156;DIMENSIONS L=1.8' W=1.5'DEPTH .008 IAW SRM 51-10-02 PARA#15 ;EVALUATED TO SIDEWALL SUPPORT;ORIGINAL THICKNESS .040 REMAINING THICKNESS .032 DAMAGE EXCEED 10% OF ORIGINAL THICKNESS FOUND TO BE OUT LIMITS IAW SRM 53-00-53-1A-2 ALLOWABLE DAMAGE 2.; [03] THIS DISCREPANCY WILL ACCOMPLISHED ON CARD TTG8Q005ZD26; [04] THIS DISCREPANCY WILL BE ACCOMPLISHED ON CUSTOMER CARD TTG8Q005ZD26.; [05] VERIFIED FLOOR TO SIDEWALL SUPPORT REPLACED ON FAULT # TTG8Q005ZD26