What was found
CORROSION ON FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BAY BS754 RBL21 WL156. ; / [01] REMOVED CORROSION ON FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BS 754RBL21 WL156;DIMENSIONS L=1.3' W=1.' DEPTH .011 IAW SRM 51-10-02 PARA#15 .EVALUATED TO SIDEWALL SUPPORT ;ORIGINAL THICKNESS .040'REMAINING THICKNESS .029' DAMAGE EXCEED 10% OF ORIGINAL THICKNESS FOUND TO BE OUT LIMITS IAW SRM 53-00-53-1A-2 ALLOWABLE DAMAGE 2;TOOL USED MICROMETER S/N 87172291 DATE DUE 05/2022.; [02] VERIFIED REMOVED CORROSION ON FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BS 754RBL21 WL156;DIMENSIONS L=1.3' W=1.' DEPTH .011 IAW SRM 51-10-02 PARA#15 .EVALUATED TO SIDEWALL SUPPORT ;ORIGINAL THICKNESS .040'REMAINING THICKNESS .029' DAMAGE EXCEED 10% OF ORIGINAL THICKNESS FOUND TO BE OUT LIMITS IAW SRM 53-00-53-1A-2 ALLOWABLE DAMAGE 2.; [03] THIS DISCREPANCY WILL ACCOMPLISHED ON CARD TTG8Q005ZD26.; [04] THIS DISCREPANCY WILL BE ACCOMPLISHED ON CUSTOMER CARD TTG8Q005ZD26.; [05] VERIFIED FLOOR TO SIDEWALL SUPPORT REPLACED ON FAULT # TTG8Q005ZD26