What was found
FLOOR PANEL 242VF HAS SEVERAL AREAS OF DELAMINATION ON UPPER AND LOWER SKINS ; / [08] VERIFIED SANDED POTTING COMPOUND AND CORE PLUG FLUSH AND CLEANED. FABRICATED REPAIR PLIES FROM BMS 9-3 TYH2 LOT# 1458851-1 IAW SRM 53-00-50-2R-6 PARA 3.G AND 3.J. AND SRM 53-00-50-2R-1 PARA 3 I.-K. OKAY TO INSTALL REPAIR PLIES.; [09] INSTALLED REPAIR PLIES AND VACUUM BAGGED FOR CURE IAW SRM 53-00-50-2R-1 PARA 3.K.-L. AND 53-00-50-2R-6 PARA G.-H.; [10] CORRECTION FOR CORRECTIVE ACTION 9.<BR><BR>ADDING 'PLIES FABRICATED USING BMS 8-201 TY3 LOT# AK1DP9074K.'; [11] VERIFIED STEPS 9 AND 10; [12] CURED REPAIR PLIES USING A HEAT LAMP IAW SRM 53-00-50-2R-1 PARA 3.M.(1) AND SRM 53-00-50-2R-6 PARA 3.M.(1).<BR><BR>THERMOMETER: ID - ATS2208 S/N - 43300740WS<BR>VACUUM GAUGE: ID - ATS2584 S/N - 5432766772; [13] UNBAGGED FLOOR PANEL 242VF IAW SRM 53-00-50-2R-6 PAR 3M(1). <BR><BR>COMPLETED SRM REPAIR 53-00-50-2R-6.; [14] VERIFIED REPAIR CURE AND UNBAGGING PER SRM 53-00-50-2R-1 AND SRM 53-00-50-2R-6; [15] VERIFIED COMPLETION OF REPAIR TO FLOOR PANEL 242VF PER SRM 53-00-50-2R-6 AND SRM 53-00-50-2R-1; [16] VERIFIED COMPLETION OF REPAIR TO FLOOR PANEL 242VF PER SRM 53-00-50-2R-6 AND SRM 53-00-50-2R-1