What was found
PANEL 192F HAS CHAFING DAMAGE ON FWD AND AFT EDGE MATING SURFACES ; / [01] IDENTIFIED PANEL 192F MATERIAL IAW SRM 53-40-70-0I-1 FIG 2 TABLE 2 ITEM [15]. <BR>REMOVED FINISH IAW AMM 51-21-11-150-815 PARA. 17. C. AND D.<BR>FOUND CHAFING DAMAGE ON INNER FWD AND AFT MATING SURFACES TO EXCEED ALLOWABLE LIMITS IAW SRM 53-40-70-1A-1 PARA. 4. B. (4). THESE AREAS WILL BE REPAIRED IAW SRM 51-70-05-2R-6. AS GIVEN IAW SRM 53-40-70-2R-1 TABLE 202.