What was found
CORROSION ON FLOOR SIDEWALL SUPPORT FWD CARGO BAY BS 480 +14 LBL 24 WL 156 ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AN SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION FROM FLOOR TO SIDEWALL SUPPORT FWD CARGO BAY BS 480+14'' LBL24 WL156; P/N 143A7501-80; IN AREA .5''X.2''X0.018'' DEEP; ORIGINAL THICKNESS 0.040''; FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2; PAR. 4.A(2) FIG. 103 DETAIL A. <BR>TOOL USED: DEPTH GAGE ID:ATS2472; DUE DATE: 06/2022; [03] VERIFIED REMOVED CORROSION FROM FLOOR TO SIDEWALL SUPPORT FWD CARGO BAY BS 480+14'' LBL24 WL156; P/N 143A7501-80; IN AREA .5''X.2''X0.018'' DEEP; ORIGINAL THICKNESS 0.040''; FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2; PAR. 4.A(2) FIG. 103 DETAIL A.; [04] FLOOR TO SIDEWALL SUPPORT FWD CARGO BAY BS480+14'' LBL 24 WL156; REPLACEMENT TO BE ACCOMPLISHED ON TASK CARD #TTG8Q005ZT2A; [05] FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT BS480+14'' LBL 24 WL156;IS ACCOMPLISHED ON TASK CARD #TTG8Q005ZT2A; [06] VERIFIED CORRECTIVE ACTION 4 & 5.; [07] CORRECTED MEASUREMENTS SECTION.; [08] VERIFIED JOB COMPLETE