What was found
FLOOR PANEL 222AF HAS PEELING FIBERS ON UPPER SURFACE ; / [01] IDENTIFIED PANEL 222AF IAW SRM 53-00-50-0I-1.FIG 2. FOUND DAMAGE AT 8' FROM FWD EDGE; FROM I/B EDGE TO O/B EDGE TO BE BEYOND ALLOWABLE LIMITS IAW SRM 53-00-50-1A-1.PARA 4.F. REQUIRES REPAIR PER SRM 53-00-50-2R-1.<BR>REMOVED 8EA INSERTS TO FACILITATE MAINTENANCE IAW SRM 53-00-50-2R-1.PARA 3.B.<BR>REMOVED APPROX. 38'X0.7' DAMAGED PLIES. FABRICATED REPAIR PLIES FROM BMS 9-3 TY H2 LOT#1458851-1 IAW SRM 53-00-50-2R-1.PARA 3.A-F; K.(1).<BR>OK TO INSTALL.; [02] VALIDATED APPLICABILITY OF SRM 53-00-50-2R-1.; [03] INSPECTED AND VERIFIED CORRECTIVE ACTION ITEMS 1 AND 2. OKAY TO INSTALL REPAIR PLIES PER SRM 53-00-50-2R-1.; [04] INSTALLED REPAIR PLIES USING BMS8-201 TY4 LOT#AK1EP9088K; VACUUM BAGGED; CHECKED FOR LEAKS USING VACUUM GAUGE ID:ATS2586 S/N:5432766772. LEAK CHECK GOOD IAW SRM 53-00-50-2R-1.PARA 3.K-M.(1).; [05] INSPECTED AND VERIFIED CORRECTIVE ACTION ITEM 4 PER SRM 53-00-50-2R-1. OKAY TO CURE REPAIR.; [06] SET TO CURE USING HEATCON ID:ATS532 SN/:15092117 IAW SRM 53-00-50-2R-1.PARA 3.L.(1)-M.(1).[09] UNBAGGED REPAIR; TRIMMED EDGES & CLEANED IAW SRM 53-00-50-2R-1 PARA 3.M. INSTALLED AND CURED (8EA) INSERTS REMOVED TO ACCOMPLISH REPAIR IAW SRM 53-00-50-2R-1 PARA 3.N AND SRM 53-00-50-2R-0 PARA 5.S.; [10] ADDING CORRECTIVE ACTION FOR ITEM 9; (CURED USING THERMOMETER ID: PER1919 S/N: 180657982).[12] REPAIR TO FLOOR PANEL 222AF WAS COMPLETED IAW SRM 53-00-50-2R-1. REPAIR COMPLETE.