As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFT CARGO COMPT. FLOOR PANEL 140CF EDGES HAVE CORROSION / MEASURED LENGTH OF CORROSION DAMAGE TO BE = 36' LIMIT = 20' PANEL 140CF IS OUT OF LIMITS IAW SRM 53-00-53-1A-1 FIG 102. FABRICATED NEW PANEL IAW AMM 25-52-01-201-801. TREATED AND PRIMED LOWER SURFACE OF PANEL IAW AMM 51-21-41-370-803 AND 51-21-73-370-804