What was found
CORROSION ON FLOOR TO SIDEWALL SUPPORT AT FWD CARGO BAY BS500+5.5 LBL25 WL156. ; / [01] EVALUATED CORROSION; FOUND 0.015 REMOVED FROM ORIG 0.040 IN A 1'X 1' AREA FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2 USING DIAL DEPTH GAUGE PART# ATS2472 S/N UNKNOWN; [02] VERIFIED CORRECTIVE ACTION ENTRY 1.; [03] REMOVED FCB LH FLOOR TO SIDEWALL SUPPORT BS396-500D; IAW SRM 51-40-02-0G-0.; [04] FABRICATED REPAIR PARTS; FOR FCB LH FLOOR TO SIDEWALL SUPPORT; BS396-500D; SPLICE AT BS 480+10; IAW SRM 53-00-53-2R-5. MATERIAL; BAC1496-444#7075T62; LOT# 1457271-1. SRM 51-40-05-0G-0; DWG 143A7500. AND; OK TO PRIME REPAIR PARTS.; [05] ALSO INCLUDING APPLIED CHEMICAL CONVERSION COATING IAW SRM 53-00-53-2R-5; [06] VERIFIED CORRECTIVE ACTION #4 & #5.<BR>OK TO PRIME REPAIR PARTS GIVEN.; [07] PRIMED AND ASSEMBLED REPAIR PARTS FOR FCB LH FLOOR TO SIDEWALL SUPPORT; BE396-500D; LBL25; IAW SRM 53-00-53-2R-5; REPAIR 5.; [08] VERIFIED CORRECTIVE ACTION ITEM 7; [09] ENAMEL TOP COAT AND CIC ACCOMPLISHED PER CUTOMER CARD# TTG8Q004G8AZ.<BR> REQUEST OK TO INSTALL.; [10] VERIFIED ENAMEL TOP COAT AND CIC ACCOMPLISHED PER CUTOMER CARD# TTG8Q004G8AZ.<BR>OK TO INSTALL.; [11] INSTALLED FCB SIDEWALL SUPPORT L/H BS 396 TO 500D LBL 25 IAW. SRM 51-40-02 AND DWG: 143A7500 REV: A; [12] VERIFIED CORRECTIVE ACTION 11; [13] VERIFIED JOB COMPLETED