What was found
CORROSION FWD CARGO STA. 500D RBL 25- LBL 25 BULKHEAD PANEL ATTACH ANGLE. (MARKED) ; / [01] BLENDED AREAS OF CORROSION ON BULKHEAD ATTACH ANGLE; FWD CARGO STA. 500D; ALLOWED 0.007; REMOVED 0.012. BLENDS ARE OUT OF LIMITS ALL IAW SRM 53-00-53-1A-2.; [02] VERIFIED OUT OF LIMITS FOR STEP1; [03] REPLACED FWD CARGO; STA. 500D; RBL25 TO LBL25 CENTER AFT BULKHEAD PANEL ATTACH ANGLE IAW SRM 51-40-02 AND TASK NUMBER 5330-E-16461-NG.; [04] VERIFIED WORK ACCOMPLISHED.; [05] VERIFIED WORK ACCOMPLISHED.