What was found
B.S. 663 LOWER COMPOSITE BULKHEAD VERTICAL SUPPORT STIFFENER IS CRACKED AT L.B.L. 26; W.L. 150; ON AFT SIDE OF BULKHEAD. ; / [01] UPDATED MEASUREMENT TABLE; [02] REMOVED CRACKED VERTICAL SUPPORT STIFFENER BS 663; LBL 26; WL 150 AFT SIDE OF BULKHEAD PER SRM 51-40-02-0G-0; [03] LOCATED AND DRILLED VERTICAL SUPPORT STIFFENER AT B.S663 LBL 26; WL 150 AFT SIDE OF BULKHEAD PER SRM 51-40-05-0G-0;DWG 111A1000. O.K TO INSTALL.; [04] VERIFIED LOCATION; DRILL UP PER SRM 51-40-05-0G-0;DWG 111A1000. OK TO INSTALL STIFFENER; [05] INSTALLED VERTICAL SUPPORT STIFFENER BS 663; LBL 26; WL 150 AFT SIDE OF BULKHEAD PER SRM 51-40-02-0G-0;DWG 111A1000.; [06] VERIFIED SUPPORT STIFFENER INSTALLATION PER SRM 51-40-02 AND DWG 111A1000; [07] COMPLETE