What was found
PANEL 194CR OUTER SURFACE DELAMINATION; 7.75' FROM I/B END; 7.5' FROM FWD EDGE ; / [01] PART/MATERIAL IDENTIFIED IAW SRM 53-60-70-0I-1 FIG 2 TABLE 2 ITEM 6 .<BR>7/16 DIA DELAMINATION EXCEEDS THE ALLOWABLE LIMITS AS GIVEN IN SRM 53-60-70-1A-1 PARA 4 A (6) .<BR>REPAIR TO BE PERFORMED IAW SRM 51-70-05-2R-2 AS GIVEN IN SRM 53-60-70-2R-1 PARA 4 D REF TABLE 201; [02] VALIDATED REPAIR PER SRM 51-70-05-2R-2; [03] PERFORMED DAMAGE REMOVAL & SURFACE PREPARATION STEPS IAW SRM 51-70-05-2R-2 PARA 4 STEPS A ; B ; & C .; [04] VERIFIED MATERIAL ID PER SRM 53-60-70-0I-1<BR>VERIFIED DAMAGE IS OUT OF LIMITS PER SRM 53-60-70-1A-1<BR>VALIDATED REPAIR PER SRM 51-70-05-2R-2 <BR>VERIFIED WORK PERFORMED PER SRM 51-70-05-2R-2;