What was found
CORROSION ON WEB AT AFT WET AREA BS987 RBL39 WL208. ; / [01] REMOVED AND EVALUATED CORROSION REMOVAL AT DISCREPANCY AREA L= 1.3' W=1.0'. NO ALLOWABLE DAMAGE FOUND ON SRM. PART TO BE REPAIR BY REPLACEMENT PER SRM 51-10-02; [02] VERIFIED; DAMAGE NOT ALLOWED AT THAT AREA; PART WILL BE REPLACED.; [03] REMOVED DAMAGE AREA L= 1.3' W=1.0' PER SRM 51-10-02 AND PERFORMED VISUAL INSPECTION WITH A 10-POWER MAGNIFYING GLASS TO MAKE SURE ALL OF THE CORROSION WAS REMOVED AND TO FIND POSSIBLE CRACKS TO SUBMIT TO ENGINEERING FOR REPAIR DISPOSITION.; [04] REMOVED 1EA FASTENER AT REWORKED AREA PER SRM 51-40-02; [05] VERIFIED CORROSION IS REMOVED PER SRM 51-10-02; [06] UT INSPECTED BLEND IAW 737 NDTM PART 4 51-00-00 PROCEDURE 2; REMAINING THICKNESS IS 0.037' ADJACENT TO 0.040'. EQUIP ID#: ATS2031 S/N: 170515011;