What was found
FWD PASSENGER COMP FLOOR STRUCUTURE WET AREA INTERCOSTAL CRACKED AROUND FASTENER HOLE BETWEEN FLOOR BEAMS BS 344 AND BS 328 LBL-46.5 ; / [01] REMOVED INTERCOSTAL AT WET AREA BS 344 AND BS328 LBL 46.5 B 737-700 SRM 51-40-02-0G-0; [02] LOCATED AND DRILLED NEW HOLES ON NEW INTERCOSTAL PER RED B737 SRM 51-40-05-0G-0; [03] VERIFIED STEPS 1 AND 2 ; OK TO INSTALL SERVICEABLE INTERCOSTAL.; [04] INSTALLED INTERCOSTAL AT WET AREA BS 344AND BS 328 LBL 46.5 B 737-700 SRM 51-40 02 -0G - 0; [05] VERIFIED ACCOMPLISHMENT OF STEP 4