What was found
CRACK STRINGER 26R LOCATED BS 540 FWD CARGO COMPARTMENT ; 2021-356670 / [01] TOOL USED PN: NORTEC 600D; SN: 210138503; CAL DUE DATE: 05-MAR-22; [02] TOOL USED: RADIUS GAGE P/N 2204A3; S/N: 408651; DUE DATE: 02FEB22.; [03] PERFORMED PERMANENT REPAIR ON STRINGER 26R LOCATED BS 540 FWD CARGO COMPARTMENT IAW B737-700 SRM 53-00-03-2R-1 REPAIR 1 FIGURE 206 AND DRAWING 143A0060 REV. A MATERIAL USED ALUMINUM SHEET P/N: 7075-T0-0.050 PO# 2021 139514; ALUMINUM SHEET P/N: 7075-T0-0.045 PO# 2021 152098.; [04] CORRECTED STEP 3: PERFORMED PERMANENT REPAIR ON STRINGER 26R LOCATED BTW BS 500D TO BS 540 FWD CARGO COMPARTMENT IAW B737-700 SRM 53-00-03-2R-1 REPAIR 1 FIGURE 206 AND DRAWING 143A0060 REV. A MATERIAL USED ALUMINUM SHEET P/N: 7075-T0-0.050 PO# 2021 139514; ALUMINUM SHEET P/N: 7075-T0-0.045 PO# 2021 152098.; [05] CERTIFIED RII MAJOR REPAIR PERFORMED.