What was found
BS 663 LOWER CHORD COMMON TO FUEL TANK CRACKED AT RBL 8, CUT & REMOVED ATTACH ANGLE IAW SRM 57-10-10-2R-5 REPAIR 5. PERFORMED DVI OF REPAIR AREA & UNDERLYING STRUCTURE. NO DEFECTS IAW SRM 57-10-10-2R-5. HFEC IAW NDT PART 6 51-00-00 PROC 16. NO DEFECTS. FABRICATED REPAIR PARTS IAW SRM 57-10-10-2R-5, REPAIR 5. TREATED AND PRIMED REPAIR PARTS & CUT EDGE IAW SRM 57-10-10-2R-5 REPAIR 5. INSTALLED REPAIR PARTS IAW SRM 57-10-10-2R-5 REPAIR 5. BONDING CHECKED GOOD. APPLIED CIC TO REPAIR AREA IAW SRM 57-10-10-2R-5 REPAIR 5. PERFORMED LEAK CHECK IAW AMM 28-11-00-400-801. NO LEAKS.