What was found
CRACK ANGLE LOCATED BETWEEN BS 907 AND BS 927 BETWEEN S-25R AND S-27R FWD LOCATION INTERNAL WATER SERVICE AREA AFT CARGO COMPARTMENT ; 2021-384547 / [11] REPLACED ANGLE AND FASTENERS LOCATED BETWEEN BS 907 AND BS 927 BETWEEN S-25R AND S-27R FWD LOCATION INTERNAL WATER SERVICE AREA AFT CARGO COMPARTMENT IAW B737-700 SRM 51-10-02 ITEM 9; SRM 51-40-02 AND DRAWING 147A7221-32; [12] RII; STEP 10 COMPLETED. <BR>PENDING SEALANT APPLICATION ON RIVETS HEAD AND AROUND OF ANGLE.; [13] REPLACED ANGLE AND FASTENERS LOCATED BETWEEN BS 907 AND BS 927 BETWEEN S-25R AND S-27R FWD LOCATION INTERNAL WATER SERVICE AREA AFT CARGO COMPARTMENT IAW B737-700 SRM 51-10-02 ITEM 9; SRM 51-40-02 AND DRAWING 147A7221-32 AND APPLIED SEALANT IAW B737-700 SRM 51-10-02; [14] TASK CARD COMPLETED <BR>RII