What was found
SUPPLEMENTAL INFORMATION: CORROSION FWD CARGO BAY FWD SHIELD BS 420 TO BS 440 RBL 25 WL 156 ; / [01] DAMAGE FOUND ON FCB FWD SHIELD FOUND TO BE OUT OF LIMIT DUE TO NO LIMIT ON SRM PART WILL BE REPAIRED BY REPLACEMENT IAW SRM 51-10-02-0G-0 PAR 9C; [02] VERIFIED DAMAGE FOUND ON FCB FWD SHIELD BS 420 - 440 RBL 25 FOUND TO BE OUT OF LIMIT DUE TO NO LIMIT ON SRM PART WILL BE REPAIRED BY REPLACEMENT IAW SRM 51-10-02-0G-0 PAR 9C.; [03] LOCATED AND DRILLED NEW FWD CARGO BAY FWD SHIELD BS 420-440 RBL 25 WL 156 PER SRM 51-40-02-0G-0 AND BOEING DWG 143A0080. <BR><BR>OK TO INSTALL; [04] VERIFIED LOCATE AND DRILL UP OF NEW SHIELD; OK TO INSTALL PER SRM 51-40-02 AND DWG 143A0080.; [05] CORRECTED MEASUREMENTS SECTION; [06] INSTALLED FWD CARGO BAY FWD SHIELD BS420-BS440; RBL 25; WL 156 PER SRM 51-40-02-0G-0 AND BOEING DWG 143A0080; [07] VERIFIED INSTALLED FWD CARGO BAY FWD SHIELD BS420-BS440; RBL 25; WL 156 PER SRM 51-40-02-0G-0 AND BOEING DWG 143A0080; [08] TASK COMPLETE