What was found
CORROSION FLOOR TO SIDEWALL SUPPORT BS 429 TO BS 433 LBL 25 WL 156 ; / [01] BLENDED CORROSION ON LH FLOOR TO SIDEWALL SUPPORT FROM BS 429- BS 433. REMOVED .010' (AT DEEPEST BLEND) MATERIAL IN A AREA MEASURING .3' X .4'. ORIGINAL THICKNESS IS .040' THEREFORE THE PART IS OUT OF LIMITS BECAUSE MATERIAL REMOVAL EXCEEDS 10% OF MATERIAL THICKNESS PER SRM 53-00-53-1A-2. STEP 4. A (2) FIGURE 103<BR><BR>THIS PART WILL BE REPLACED ON CUSTOMER CARD: TTG8Q0067PPS<BR><BR>DEPTH GUAGE USED:<BR>ID:ATS401<BR>S/N: UNKNOWN<BR>DATE:07/2021<BR>DUE:07/2022; [02] VERIFIED BLEND AREA EXCEEDS ALLOWABLE LIMITS PER SRM 53-00-53-1A-2. STEP 4. A (2) FIGURE 103; AND WILL BE REPLACED ON TTG8Q0067PPS; [03] CORRECTED MEASUREMENTS SECTION