What was found
CRACKED FLOOR SUPPORT BS 277-294 BL 0 WL 208 ; / [01] REMOVED CRACKED SUPPORT AT BS 277-294 BL0 WL 208; LOCATED AND DRILLED NEW SUPPORT IAW SRM 51-40-02 SRM 51-40-05. REQUEST OKAY TO INSTALL; [02] VERIFIED REMOVED CRACKED SUPPORT AT BS 277-294 BL0 WL 208; LOCATED AND DRILLED NEW SUPPORT IAW SRM 51-40-02 SRM 51-40-05. REQUEST OKAY TO INSTALL; [03] INSTALLED NEW INTERCOSTAL PER SRM 51-40-02 AND DWG 141A5400; [04] VERIFIED INSTALLATION OF NEW INTERCOSTAL PER SRM 51-40-02 AND DWG 141A5400; [05] VERIFIED INSTALLATION OF NEW INTERCOSTAL PER SRM 51-40-02 AND DWG 141A5400