CRACKED FLOOR SUPPORT BS 344-360 BL 0 WL 208 ; / [01] ET INSPECTED SUSPECTED CRACK IAW 737 NDTM PART 6 51-00-00 PROCEDURE 23; VERIFIED CRACK EXISTS.<BR>CAL ID IS000450 N500D; [02] REMOVED INTERCOSTAL AT BS344-360 BL0 WL 208; PER SRM 51-40-02. LOCATED AND DRILLED NEW INTERCOSTAL PER SRM 51-40-05 AND DWG141A5400. REQUEST OK TO INSTALL.; [03] VERIFIED LOCATION AND DRILL UP PER SRM 51-40-05 AND DWG 141A5400. FLOORBOARD HOLES STILL REQUIRED; [04] INSTALL NEW INTERCOSTAL BS 344-360 BL 0 WL208 IAW SRM 51-40-02 AND DWG 141A5400; [05] VERIFIED INSTALLATION AND DRILLING OF FLOORBOARD HOLES IN INTERCOSTAL PER SRM 51-40-02 AND DWG 141A5400.