What was found
CORROSION ON FORWARD CARGO FLOOR TO SIDEWALL SUPPORT AROUND FASTENER HOLE, BS 500+13, LBL 24, WL 154. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2, FIGURE 103 DETAIL D. FABRICATED AND LOCATED AND DRILLED FCB FLOOR TO SIDEWALL SUPPORT AND SPLICE REPAIR IAW SRM 53-00-53-2R-6, 51-40-05, & DWG:143A7501 REV B. INSTALLED SPLICE REPAIR ON FCB LEFT HAND FLOOR TO SIDEWALL SUPPORT AT BS 480 TO 500 LBL 24 WL 154 IAW SRM53-00-53-2R-6; [21] INSTALLED FCB FLOOR TO SIDEWALL SUPPORT AT BS 500D - BS 369 LBL 24 WL 154 IAW SRM 51-40-02 AND DWG 143A7500 ID:0017 REV: A AND DWG 143A7505 ID:0009 REV: A;