What was found
CORROSION ON ACB FLOORBOARD SPLICE STRAP AT BS 767 +5.5; LBL 18 TO RBL 14; WL 155.5 ; / [01] NO LIMITS FOUND IN SRM REPAIR BY REPLACEMENT IAW SRM 51-10-02-0G-0; STEP 9. C; [02] APPLIED GEL TAPE AND INSTALLED AFT CARGO FLOORBOARD SPLICE STRAP PO# 929373 AT BS 767 +5.5 WL 155.5 IAW AMM 25-52-10-400-801; [03] APPLIED GEL TAPE AND INSTALLED NEW AFT CARGO FLOORBOARD SPLICE STRAP PO#829373 AT BS 767 +5.5 WL 155.5 IAW AMM 25-52-10-400-801; [04] VERIFIED CORRECTIVE ACTION 1; 2; AND 3.; [05] UPDATED MEASUREMENTS