What was found
CORROSION BS727A+14 RBL24 WL152 FLOOR TO SIDEWALL SUPPORT ; CORROSION BS727A+14 RBL24 WL152 FLOOR TO SIDEWALL SPPORT / [01] REMOVED CORROSION ON FLOOR TO SIDEWALL SUPPORT AT BS 727+14'; LBL24; WL 152 PER SRM51-10-02-0G-0 MEASURE L=7.5'X W=1'X D=0.010' MAX. MAT LOSS IS 0.010'; REMAINING THICKNESS IS 0.030'; ORIGINAL THICKNESS IS 0.040' (BAC1496-444) FOUND TO BE OUT OF LIMITS; REWORKED AREA PER SRM53-00-53-1A-2; ALLOWABLE DAMAGE PARAG. 4.A (2) DETAIL (E) FIG 103.- MICROMETER;S/N 65092939 DUE 03/2022.; [02] THIS DISCREPANCY WILL ACCOMPLISHED ON CARD TTG8Q006H1B2; [03] VERIFIED THIS DISCREPANCY WILL BE ADDRESSED ON CC# TTG8Q006H1B2