What was found
CORROSION AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT BS 727A - 787+15, LBL21, WL156. REMOVED CORROSION AND FOUND OUT LIMITS SRM 53-00-53-1A-2. REMOVED AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT IAW SRM 51-40-02-0G-0. FABRICATED, LOCATED, AND DRILLED A FLOOR TO SIDEWALL SUPPORT IAW SRM 51-40-05-0G-0, AND DWG 146A7500. FABRICATED REPAIR SPLICE IAW SRM 53-00-53-2R-5, REPAIR 5. INSTALLED FLOOR TO SIDEWALL SUPPORT IAW SRM 51-40-02-0G-0, AND DWG 146A7500.