What was found
CORROSION AFT CARGO BAY FWD SHIELD BS767+3 TO BS787 RBL22 WL156 ; / [01] CORRSION ON THE FWD SHIELD FROM BS767+3 TO BS787 RBL 22 WL 156 FOUND TO BE OUT OF LIMITS DUE TO NO SRM ALLOWABLE DAMAGE. THE STRUCTURAL ITEM WILL BE REPAIRED BY REPLACEMENT IAW SRM 51-10-02 PARA 9C; [02] REMOVED SHIELD WEB FROM BS767 TO BS787 RBL 21 IAW SRM 51-40-02; [03] VERIFIED CORROSION REMOVAL IS OUT OF LIMITS PER DUE TO NO ALLOWABLE LIMITS IN THE SRM. SHIELD WILL BE REPLACED.; [04] LOCATED AND DRILLED NEW ACB SHIELD WEB PN#146A8127U12 PO#835804 FROM BS767-BS787 RBL 21 IAW SRM 51-40-02 AND IAW DWG#146A0081 INSTALLED ACB FWD SHIELD WEB FROM BS767-BS787 RBL 21 IAW SRM 51-40-02 AND IAW DWG#146A0081